- Rapid action
- Ready to use
- Non rusting
- Excellent material compatibility
- Flexible reprocessing
- Proven Safety
- Long Life
-
PARTICULARS SPECIFICATIONS Ortho-phthaladehyde 0.55% With chelating agents buffer, corrosion inhibitors & aqua
Mi-OPA, is a rapid action high level disinfectant. The solution is able to killall types of bacteria, mycobacterium tuberculosis, viruses and fungi in less than 5 minutes.
This increases the turn around time for scopes and devices, thereby increasing operational efficiency of the hospital.
-
Mi-OPA is available in a ready to use, stable formulation. There is no need to dilute or activate the solution.
-
Mi-OPA is a neutral pH solution. Combined with corrosion inhibitors it provides a non rusting solution for high level disinfection.
-
METALS PLASTICS ELASTOMERS ADHESIVES Aluminium Polymethylmethacrylate (Acrylic) Polychloroprene (Neoprene) EPO-TEK 301 Anodized aluminium Nylon1 Kraton G1 Epoxy3 Brass Polyethylene terephthalate (Polyester) Polyurethane EPO-TEK 353ND Carbon steel Polyester Silicone rubber Epoxy Chrome plated brass Polyvinylchloride (PVC) Natural rubber latex 1 Chrome plated steel Acrylonitrile/butadiene/styrene (ABS) Copper Polysulfone & Polycarbonate Nickel sliver alloy Polyethylene Stainless steel Polypropylene Titanium Acetal & PTFE Tungsten carbide Polyamide
-
Mi-OPA can be used for manual disinfection as well as automatic reprocessing of instruments, scopes and medical devices.
-
Mi-OPA has minimal inhalation exposure risk to low vapour pressure. Its near neutral pH level ensures compatibility with instruments well as endoscopes.
Mi-OPA is safe for patients and health care professionals.
-
Mi-OPA can be used for manual disinfection as well as automatic reprocessing of instruments, scopes and medical devices.
-
Mi-OPA, is a high level disinfectant intended to disinfect heat sensitive reusable medical devices. It has excellent material compatibility and is suitable for reprocessing of instrument mode of rubber, plastic, metal, glass and porcelain. It can be used for manual, semi-automatic as well as completely automatic procedures. It can also be used in ultrasound baths.
-
Manual Processing: Immerse device completely in Mi-OPA, filling all Lumens and eliminating air pockets. Immerse for minimum 5 minutes at 25deg C or 12 minutes at 20deg C to achieve high level disinfection.
Re-processing using Automatic Endoscope Re-processor: Set the temperature to 25deg C with an immersion time of 5 minutes.
After removing the device from Mi-OPA, wash it thoroughly with large volume of water Use sterile water if required.
-
Store at controlled room temperature, 15deg to 30deg C.
For external use only
Keep soaking trays covered at all times
Avoid direct contact with skin,eyes and clothing
Wear personal protective gear like rubber gloves, eye shield while handling
Wash thoroughly with soap and water after handling
Flush eyes with fresh water in case of contact
In case of emergency, seek medical help
Keep out of reach of children